Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Front Public Health ; 11: 1148105, 2023.
Article in English | MEDLINE | ID: mdl-36923047

ABSTRACT

Background: Psychological workplace violence (WPV) is the primary form of workplace violence suffered by nursing interns. Psychological WPV not only damages the physical and mental health of nursing interns, but also has a negative impact on their work quality and career choice. Aim: To investigate the characteristics and types of psychological WPV suffered by nursing interns in China, analyze the influencing factors of psychological WPV among nursing interns, and explore the influence of psychological WPV on the professional commitment of nursing interns. Methods: The subjects were 1,095 nursing interns from 14 medical colleges in Shandong Province. The data were collected electronically using the psychological WPV against nursing interns questionnaire and the professional commitment scale of nursing. The frequency and component ratio were used to describe the incidence and characteristics of psychological WPV. Binary logistic regression was used to analyze the influencing factors of psychological WPV, and linear regression investigated the influence of psychological WPV on the professional commitment of nursing interns. Results: In the study, 45.0% (n = 493) of nursing interns suffered at least one incidence of psychological WPV during clinical practice, mainly discrimination and verbal abuse. Patients and their relatives were the main perpetrators of psychological WPV. Discrimination and lack of trust were the two main reasons behind psychological WPV. Furthermore, 75.9% of psychological WPV incidents were not effectively reported. Logistic regression showed that clinical internship duration, place of family residence, and hospital level were the influencing factors of psychological WPV among nursing interns. Linear regression results showed that psychological WPV had a negative effect on nursing interns' professional commitment. Conclusion: Psychological WPV against nursing interns is highly prevalent in China, negatively impacting their professional commitment. It is suggested that colleges should introduce courses for nursing interns to understand and cope with psychological WPV before entering clinical practice, and hospitals should establish a mechanism to prevent, cope with, report, and deal with psychological WPV to effectively reduce the incidence of psychological WPV against nursing interns, improve their ability to cope with psychological WPV, and enhance their professional commitment.


Subject(s)
Workplace Violence , Humans , Cross-Sectional Studies , Workplace Violence/psychology , China/epidemiology , Surveys and Questionnaires , Mental Health
2.
Magn Reson Med ; 88(6): 2621-2632, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36045635

ABSTRACT

PURPOSE: To develop and validate an MRI-based radiomics model for differentiating invasive placentas in patients with high risks. METHODS: A total of 181 pregnant women suspected of placenta accreta spectrum (PAS) disorders and who underwent MRI for placenta evaluation were retrospectively enrolled. The data set was randomly divided into the training (n = 125; invasive = 63, noninvasive = 62) and test (n = 56; invasive = 28, noninvasive = 28) groups. Radiomics features were extracted from half-Fourier acquisition single-shot turbo spin echo (HASTE) and sagittal true fast imaging in steady-state precession (TRUFISP) sequences independently and mainly selected based on their correlations with invasive placentas to construct two radiomics signatures including HASTE-Radscore and TRUFISP-Radscore. Then, the predictive performance of radiomic signatures, clinical features, radiographic features, and their combination were evaluated. The model with the best predictive performance was validated with its discrimination ability, calibration, and clinical usefulness. RESULTS: Five radiomics features from HASTE and three radiomics features from TRUFISP were retained, respectively, for predicting invasive placentas. The combination of radiomics signatures and clinical features including prior cesarean delivery, placenta previa, and radiographic feature, the placental thickness resulted in the best discrimination ability, with area under the curve of 0.898 (95% confidence interval [CI] 0.844-0.9522) and 0.858 (95% confidence interval 0.7514-0.9655) in the training and test cohort, respectively. The combined model showed a significantly better area under the curve performance and clinical usefulness than independent clinical or radiographic model according to DeLong test (p < .05), net reclassification improvement and integrated discrimination improvement analysis (positive improvement) and decision curve analysis (higher net benefit). CONCLUSIONS: The T2 -weighted imaging MRI radiomics model could serve as a potential prenatal diagnosis tool for identifying invasive placentas in patients with high risks.


Subject(s)
Placenta Accreta , Placenta Previa , Female , Humans , Magnetic Resonance Imaging/methods , Placenta/diagnostic imaging , Placenta Accreta/diagnostic imaging , Placenta Previa/diagnosis , Pregnancy , Retrospective Studies
3.
Abdom Radiol (NY) ; 47(12): 4237-4244, 2022 12.
Article in English | MEDLINE | ID: mdl-36114883

ABSTRACT

INTRODUCTION: This study aimed to identify if placental thickness measured from MRI images correlated with placenta percreta in patients with placenta previa. METHODS: Placental thickness was retrospectively measured in 161 patients from July 2018 to August 2020. The measurements were performed at the thickest part of the placenta in the lower uterine segment on the mid-sagittal plane MR images by two independent radiologists. Intraoperative and pathologic findings were the standard of reference. Univariate and multivariate analyses were performed to identify the relationship between clinical features, placental thickness, and placenta percreta. The predictive ability of placental thickness was demonstrated using receiver operating characteristic curve analysis. RESULTS: Placental thickness in patients with placenta percreta was significantly higher than in patients with placenta increta, placenta accreta, and normal placentas (p < 0.05). Multivariate analysis revealed that placental thickness was the only independent risk factor for placenta percreta. The cutoff value of placental thickness was 4.35 cm for differentiating placenta percreta in patients with placenta previa. DISCUSSION: Patients with placenta percreta had the highest placental thickness. Placental thickness was correlated with placenta percreta.


Subject(s)
Placenta Accreta , Placenta Previa , Humans , Female , Pregnancy , Placenta , Retrospective Studies , Magnetic Resonance Imaging/methods
4.
World J Gastrointest Oncol ; 14(8): 1585-1593, 2022 Aug 15.
Article in English | MEDLINE | ID: mdl-36160753

ABSTRACT

BACKGROUND: Ewing sarcoma (ES) is an aggressive small round cell tumor that usually occurs in younger children and young adults but rarely in older patients. Its occurrence in elderly individuals is rare. ES of the ileum with wide multiorgan metastases is rarely reported and difficult to distinguish radiologically from other gastrointestinal tract tumors. CASE SUMMARY: A 53-year-old man presented with right lower quadrant pain for 2 wk. Computed tomography results showed a heterogeneous mass within the ileum and widespread multiorgan metastases. This mass was biopsied, and pathological examination of the resected specimen revealed features consistent with an extraskeletal ES. CONCLUSION: This case emphasizes the importance of recognizing this rare presentation in the small intestine to broaden the differential diagnosis of adult intraabdominal tumors.

5.
Placenta ; 126: 76-82, 2022 08.
Article in English | MEDLINE | ID: mdl-35785692

ABSTRACT

INTRODUCTION: This study aims to identify whether placental thickness and cervical length measured by MRI correlate with postpartum hemorrhage (PPH) in patients at high risk for placenta accreta spectrum (PAS) disorders. METHODS: The placental thickness and cervical length of 200 patients from October 2017 to October 2021 were retrospectively measured. The mid-sagittal plane of the placentas was measured by 2 independent radiologists using MRI. Partial correlation analysis was used to characterize the correlation between placental thickness, cervical length and estimated blood loss during surgery. The correlation between clinical features, placental thickness, cervical length and PPH was evaluated with univariate and multivariate analyses. A nomogram was constructed based on the logistic regression. RESULTS: Placental thickness was positively correlated with the estimated blood loss during delivery, while cervical length had a negative correlation with it, based on the adjustment for gestational age. Multivariate analyses revealed that prior cesarean section, placenta previa, increased placental thickness(≧4.35 cm) and short cervical length(< 3.05 cm) were independent risk factors for PPH. When the 4 risk factors were combined together, the AUC was the highest, 0.773 (95%CI 0.707-0.840). DISCUSSION: Placental thickness and cervical length correlated with PPH. The nomogram constructed based on prior cesarean section, placenta previa, placental thickness and cervical length can be used to recognize patients with a higher risk of PPH.


Subject(s)
Placenta Accreta , Placenta Previa , Postpartum Hemorrhage , Cesarean Section/adverse effects , Female , Humans , Magnetic Resonance Imaging , Placenta/diagnostic imaging , Placenta Accreta/diagnostic imaging , Placenta Accreta/etiology , Placenta Previa/diagnostic imaging , Placenta Previa/etiology , Postpartum Hemorrhage/diagnostic imaging , Postpartum Hemorrhage/etiology , Pregnancy , Retrospective Studies
6.
Ann Transl Med ; 10(6): 269, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35434012

ABSTRACT

Background: Using magnetic resonance imaging (MRI) to explore the changes in microvascular perfusion fraction and the heterogeneity of the placenta during pregnancy. Methods: We retrospectively reviewed 24 patients with normal pregnancies who underwent standard diffusion-weighted, diffusion kurtosis, and intravoxel incoherent motion MRI. The mean, minimum and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard diffusion-weighted imaging (DWI), the diffusion coefficient (MD) and diffusion kurtosis (MK) from diffusion kurtosis imaging (DKI), and the pure diffusion coefficient (D), pseudo-diffusion coefficient (D*) and perfusion fraction (f) from intravoxel incoherent motion MR imaging (IVIM) were calculated from the whole placenta volumetric analysis and correlated with gestational age (GA) and volume of the placenta. Results: A significant positive correlation was found between eADC mean, eADC max, MK mean, MK max, the volume of the whole placenta, and GA, and a negative correlation was found between ADC mean, ADC min, MD min, D mean, D min, D* min and GA. The f mean and MK max values positively correlated with the volume of the whole placenta. Conclusions: eADC mean, eADC max, MK mean, MK max values increased with GA, while ADC mean, ADC min, MD min, D mean, D min, D* min decreased with GA. Secondly, the f mean and MK max also increased with placental volume. These results suggest the potential of diffusion and perfusion parameters to evaluate the placenta during its development using different DWI models.

7.
BMC Pregnancy Childbirth ; 22(1): 349, 2022 Apr 22.
Article in English | MEDLINE | ID: mdl-35459146

ABSTRACT

BACKGROUND: To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in differentiating placenta accreta spectrum (PAS) disorders. METHODS: A total of 65 patients with PAS disorders and 27 patients with normal placentas undergoing conventional DWI, IVIM, and DKI were retrospectively reviewed. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and mean diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured from the volumetric analysis and compared between patients with PAS disorders and patients with normal placentas. Univariate and multivariated logistic regression analyses were used to evaluate the value of the above parameters for differentiating PAS disorders. Receiver operating characteristics (ROC) curve analyses were used to evaluate the diagnostic efficiency of different diffusion parameters for predicting PAS disorders. RESULTS: Multivariate analysis demonstrated that only D mean and D max differed significantly among all the studied parameters for differentiating PAS disorders when comparisons between accreta lesions in patients with PAS (AP) and whole placentas in patients with normal placentas (WP-normal) were performed (all p < 0.05). For discriminating PAS disorders, a combined use of these two parameters yielded an AUC of 0.93 with sensitivity, specificity, and accuracy of 83.08, 88.89, and 83.70%, respectively. CONCLUSION: The diagnostic performance of the parameters from accreta lesions was better than that of the whole placenta. D mean and D max were associated with PAS disorders.


Subject(s)
Placenta Accreta , Biomarkers , Diffusion Magnetic Resonance Imaging/methods , Diffusion Tensor Imaging/methods , Female , Humans , Placenta Accreta/diagnostic imaging , Pregnancy , ROC Curve , Retrospective Studies , Sensitivity and Specificity
8.
Abdom Radiol (NY) ; 47(3): 1150-1156, 2022 03.
Article in English | MEDLINE | ID: mdl-35072784

ABSTRACT

OBJECTIVE: To identify if placental thickness measured from MRI images correlates with placenta accreta spectrum (PAS) disorders. METHODS: Placental thickness of 245 patients was retrospectively measured from October 2016 to March 2020. The measurement was made at the thickest portion of the placenta on the mid-sagittal plane of the placenta from MRI by two independent radiologists. Surgical report and pathology of the delivered placenta were used as a reference standard. Association between clinical features, placental thickness, and PAS disorders was evaluated with univariate and multivariate analyses. The inter-reader and intra-reader reproducibility of the measurements and receiver operating characteristic curve analysis were also performed. RESULTS: Placental thickness was significantly higher in patients with PAS disorders (3.45 cm) than that in patients without PAS disorders (2.90 cm) (p < 0.05). Multivariate analyses revealed that prior cesarean section, placenta previa, and placental thickness > 4 cm were independent risk factors for PAS disorders. The inter-reader and intra-reader reproducibility of placental thickness measurement were 0.979 (95% CI 0.960-0.989) and 0.981 (95% CI 0.9640-0.990), respectively. CONCLUSION: The reproducibility of the measurement made from MRI images was high between two radiologists. Patients with PAS disorders had increased placental thickness. Placental thickness > 4 cm correlated with PAS disorders.


Subject(s)
Placenta Accreta , Placenta Previa , Cesarean Section , Female , Humans , Magnetic Resonance Imaging/methods , Placenta/diagnostic imaging , Placenta Previa/diagnostic imaging , Pregnancy , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...